Subminiature load buttons
Robotics fingertips & miniature instruments
- Diameter
- Ø6 / Ø8 / Ø9.5 mm
- Capacity
- 1–250 N
Select a miniature load cell for surgical robotics by its installed force path, cable routing and validation requirements. Compare the subminiature sensing envelope with the OEM pump sensing platform.
Request a configuration review ↗| Outer diameter (OD) | Height (H) | Series / fit | Button radius | Capacity (N / kgf / lbf) |
|---|---|---|---|---|
| Ø6 / Ø8 / Ø9.5 mm | 2.8–4 mm | MT-BLC-SUB ↗Robotics fingertips & miniature instruments | Spherical; drawing-specific | 1 N / 0.102 kgf / 0.225 lbfto 250 N / 25.493 kgf / 56.202 lbf |
| OEM envelope review | OEM envelope review | MT-BLC-MED ↗Infusion pumps & medical device development | Spherical; drawing-specific | 5 N / 0.51 kgf / 1.124 lbfto 100 N / 10.197 kgf / 22.481 lbf |
The MT-BLC-SUB family supports axial compression sensing behind a contact pad. Keep tangential loads out of the sensor, define a hard stop and test the full finger motion for cable strain. Surgical instrument developers should specify cleaning exposure, isolation needs and any sterilisation process before a configuration is proposed.
Button load cells in medical devices measure the reaction force at a mechanical interface. Syringe geometry, friction, tube stiffness and drive alignment affect how that force relates to fluid pressure. Use MT-BLC-MED for OEM integration and validate thresholds on the complete device.
Specify zero drift, temperature conditions, overload, expected cycles and lot traceability. Ask for an agreed test plan and configuration records. Do not infer medical certification or sterilisation suitability from the miniature sensor form factor.
Robotics fingertips & miniature instruments
Infusion pumps & medical device development
Need an application-specific answer?
Talk through your force path ↗
Include preload, normal compression peaks and credible overloads. Select a range that resolves the minimum force of interest while leaving mechanical margin, and add a fixture overload stop.
Kilograms describe mass. Use kgf when expressing force: 1 kgf = 9.80665 N. The tables show N, kgf and lbf together; dimensions and ratings remain model-specific.
Send the complete original model, drawing revision, capacity and electronics details. We review mechanical and electrical interfaces and agree a sample correlation test before compatibility is confirmed.
No. Cable, sensor body and amplifier ratings are separate. Request a +150°C or +200°C sensing configuration with the actual thermal conditions and agreed zero/span limits.
A bare mV/V bridge normally needs a compatible conditioner. Specify an MT-AMP-KIT with 0–10V, 4–20mA or an agreed RS485 interface, plus system calibration and force mapping.
Send OD × height, peak force and output. We’ll start with the fit.