Sensor body
Request +150°C or +200°C body operation with dwell, cycling and load profile. These are engineering options requiring a released configuration and test evidence.
An MT-BLC-LBM thermal configuration for hot press tooling, moulds and heated battery fixtures. Specify the temperature at the body, cable exit and electronics separately before selecting a qualification plan.

| Outer diameter (OD) | Height (H) | Button radius | Capacity (N / kgf / lbf) | Drawing / selection |
|---|---|---|---|---|
| Ø12.7 mmMT-BLC-LBM-HT | Thermal configuration drawing required | Spherical; request exact R | 50 N / 5.099 kgf / 11.24 lbfto 10,000 N / 1,019.716 kgf / 2,248.089 lbfNo dimension × range combination assumed | Select envelope ↗PDF / STEP: request |
| Ø19 mmMT-BLC-LBM-HT | Thermal configuration drawing required | Spherical; request exact R | 50 N / 5.099 kgf / 11.24 lbfto 10,000 N / 1,019.716 kgf / 2,248.089 lbfNo dimension × range combination assumed | Select envelope ↗PDF / STEP: request |
| Ø25.4 mmMT-BLC-LBM-HT | Thermal configuration drawing required | Spherical; request exact R | 50 N / 5.099 kgf / 11.24 lbfto 10,000 N / 1,019.716 kgf / 2,248.089 lbfNo dimension × range combination assumed | Select envelope ↗PDF / STEP: request |
Radius, tolerances, overload, natural frequency and deflection are drawing- and range-specific. They are not assigned from an original manufacturer’s product or a reference photograph.
Series options are not a full cross-product of every dimension and capacity. Button radius, tolerances, overload and model-specific performance are confirmed on the released drawing and quotation.
Request +150°C or +200°C body operation with dwell, cycling and load profile. These are engineering options requiring a released configuration and test evidence.
The +180°C cable add-on is a separate component option. A +200°C body request needs a separately suitable cable, termination and mounting arrangement. Keep the amplifier in its rated environment.
Agree zero and sensitivity drift, thermal gradients, warm-up and compensation over the actual measurement range. Verify in the complete fixture.

The pictured form is a construction reference. The photograph does not establish high-temperature capability.
A compact sensor only measures correctly when the surrounding fixture supports it correctly.
Machine a rigid, flat seat from the exact outline. Locate the sensor without squeezing the case or bypassing the sensing load path.
Align compression with the sensing axis. Keep the tool clear of the cover and outer case; a spherical top helps accommodate small alignment differences.
Provide a dedicated exit channel and jacket retention. Specify flexing, bend space and a strain-relief spring or sleeve with the configuration.
Performance values are series design envelopes, not a certificate for a released unit. Review the evidence to request ↗
Share the maximum diameter, installed height and compression range. We’ll review the force path, propose a series and confirm the drawing and output configuration.
Prefer email? Contact sales@magatom.com. Inquiries are received by our dedicated button load cell mailbox.